Envirotemp™ FR3™ fluid is designed for use in new and existing transformers, and also in retrofilling applications for mineral oil transformers. The revolutionary FR3 fluid is the first dielectric coolant to have the Environmental Technology Verification (ETV) report issued by the United States Environmental Protection Agency.
Extremely reliable, FR3 fluid has more than a decade of field experience in over 300,000 transformers around the world. Take a huge step in minimizing the impact your business has on the environment by simply switching to FR3 fluid; after all, it’s only natural.
- Bio-based, sustainable, natural ester dielectric coolant
- Formulated from seed oils and performance enhancing additives.
- Does not contain petroleum, halogens, silicones, corrosive sulfur, or any other questionable material.
- Listed in the US Federal BioPreferred Program, making them readily identifiable as BioPreferred to all applicable Federal agencies.
- FM approved when used in Envirotran transformers
Industrial Tests can provide complete turnkey installation of Envirotemp™ FR3™ dielectric fluid for almost any substation-size transformer on your system. We can advise on the suitability of a unit for retrofilling, suggest other alterations and repairs you may want us to make at the same time and take care of disposing of your non-PCB oil. With many FR3 fluid retrofills successfully completed, we have the training and expertise to get the job done right!
Envirotemp™ FR3™ fluid is a biodegradable dielectric coolant made from a formulation which includes vegetable oils and is proven to add value to new and retrofilled power equipment, possibly SAVING YOU MONEY in several ways:
- Lower total life cycle costs due to extended insulation paper thermal life by a factor of 5–8 times (verified by Cooper Power Systems using IEEE standard tests).
- Delayed asset replacement because FR3 fluid-cooled transformers experience a slower aging rate of cellulose insulation compared to mineral oil-filled transformers.
- Lower personnel and equipment costs due to greater flexibility when selecting installation sites along with simplified fire safety and installation requirements.
- Lower insurance and liability costs due to greatly reduced risk of fire (dependent on insurance company policies).
- Lower clean-up costs in the event of a leakage (dependent on geographical regulations and other factors).
- Slower insulation aging during periods of overload if increased output, rather than longer equipment life, is a primary goal.
In addition to retrofills, Industrial Tests has the equipment, experience and capability to complete repairs and upgrades you may elect to perform while your transformer is drained of oil such as transformer dryouts, regasketing or bushing replacements; combining services can minimize costs and transformer downtime.